Designed for applications requiring a maximum amount of output. Made from 16-gauge cold rolled steel housing and powder-coated in safety orange with 3 blade impeller. Powered by a 1-1/2 hp, 3450 RPM, UL listed and CSA certified motor. Comes with an interchangeable flange for intake or exhaust mounting, integrated carry handles for easy transport, a steel/zinc plated grill and four rubber feet are added features of this powerhouse unit.
Unit of Measure

Motors

N/A Class I, Groups C, D; Class II, Groups F, G

EX Plugs

N/A Class I, Div. 1&2, Groups B, C, D; Class II, Div. 1&2, Groups F, G

Package Type

N/A Each

Units Per Package

N/A 1

Length

N/A 19 in48.2 cm

Width

N/A 22 in55.8 cm

Height

N/A 22-1/2 in57.1 cm

Weight

N/A 79 lb35.8 kg

Free Air

N/A 6468 ft³/min10989 m³/h

One 90 Degree Bend

N/A 4314 ft³/min7330 m³/h

Two 90 Degree Bends

N/A 3922 ft³/min6664 m³/h

Note for Flow Rate

N/A Air flow determined at 60 Hz

Power

N/A 1-1/2 hp

Certifications

N/A Canadian Standards Association (CSA) Certified Underwriter Laboratories (UL) Listed

Voltage

N/A 115 V

Alternating Current (AC) Voltage

N/A 208 to 230 V

Frequency

N/A 60 Hz

Speed

N/A 3450 rpm

Current Draw

N/A 8.4 to 7.7 A15.4 A

Protection

N/A Thermal, Automatic Reset

Construction

N/A
  • Complete unit epoxy powder-coated in orange
  • Interchangeable flange for intake or exhaust side mounting
  • 16-gauge cold rolled steel housing
  • Integrated carry handles
  • Steel grill (zinc plated), equipped with four rubber feet
  • Duct grounding lug
  • NOTE: EX blowers require an explosion-proof socket (PN 9503-03: 125V)
  • Cord: 25' (7.63 m) 12/3 AWG SOOW 600V
  • Plug: NEMA 20 Amp, 125V, Explosion-Proof

Fan

N/A Anti-Static glass reinforced polyamide (PAGAS) three blade fan with aluminum hub

Accessories

N/A
  • Black, single-ply, neoprene coated, statically conductive vinyl/polyester material, temp. resistant up to 250° F (121.1° C)
  • Retractable, non-collapsible design, Class 1 hard drawn spring steel wire helix (meets ASTM 227 specs)
  • Gr

N/A When using statically conductive ducting, the integrated grounding wire must be properly grounded to the blower chassis OR linked to any additional grounding wire or duct used (as shown). Refer to User Manual for detailed instructions.

EX Rated Receptacle

N/A Iron mounting box with triple coat finish and spring-loaded door to keep out dust when in use. When plug is not in use, a neoprene gasket inside receptacle seals around plug to keep out dirt, water, dust, etc.

Note

N/A Made in the USA