The EAGLE 2 is the solution for just about any portable gas monitoring situation. Equipped with features that are not available on competitive units, the EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. The EAGLE 2 offers easy access to controls such as auto-calibration, alarm silence, demand zero, peak hold, and methane elimination. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting.
Unit of Measure

Brands

N/A RKI Instruments

Enclosure

N/A Weatherproof, Chemical Resistant, Anti RFI / EMI Coated High Impact Polycarbonate - PBT Blend. Can Operate in Rain or be Set into 2.0" of Water Without Leakage. Ergonomically Balanced with Rugged Top Mounted Handle.
Weight1 N/A 3.8 lb1.72 kg

Detection Principle

N/A Catalytic Combustion Electrochemical Galvanic Infrared Photo Ionization Thermal Conductivity

Sensor Life

N/A 2 Years Under Normal Conditions.

Sampling Methods

N/A Powerful, Long-life Pump (Over 6000 hours) Can Draw Samples Over 125 feet. Flow Rate Approximately 2.0 SCFH.

Languages

N/A Readout can Display in 5 Languages (English, French, German, Italian, or Spanish).

Alarms

N/A 2 Alarms per Channel Plus TWA and STEL Alarms for Toxics. The Two Alarms are Fully Adjustable for Levels, Latching or Self Reset, and Silenceable.

Alarm Method

N/A Buzzer 95 dB at 30 cm, Four High Intensity LED's.

Controls

N/A 4 External Glove Friendly Push Buttons for Operation, Demand Zero, and Auto calibration. Buttons also Access LEL/ppm, % Vol. Alarm Silence, Peak Hold, TWA/STEL Values, Battery Status, Conversion Factors, and Many other Features.

Continuous Operation

N/A At 70 ºF, (21 ºC) 16 Hours Using Alkaline Batteries, or 18 Hours Using Ni-MH.

Power Source

N/A 4 Alkaline or Ni-MH, Size C Batteries (Charger has Alkaline Recognition to Prevent Battery Damage if Charging is Attempted with Alkaline).

Operating Temperature

N/A -20 to 50 ºC-4 to 122 ºF
Operating Relative Humidity (RH) Range2 N/A 0 to 95 %

Response Time

N/A 30 Seconds to 90% of Range (for Most Gases) Using Standard 5 Feet Hose.

Safety Rating

N/A Intrinsically Safe, Class I, Division 1, Groups A, B, C, D.

Approvals

N/A Canadian Standards Association (CSA) European Conformity (CE)

Material Warranty

N/A 2 year

Workmanship Warranty

N/A 2 year

Photoionization Detector (PID) Sensor Warranty

N/A 1 year

Package Type

N/A Each

Units Per Package

N/A 1

Length

N/A 9.5 in241 mm

Width

N/A 5-1/4 in140 mm

Height

N/A 5.875 in149 mm

Display

N/A Backlit 128 x 64 graphics display. Viewed through window in case top. Displays readings & status of all 6 channels simultaneously. Backlight, illuminates for alarms and on demand with adjustable time. Optional mode allows automatic or manual scrolling display of just one gas at a time with very large characters.

N/A

  • Monitor LEL, O2, CO, and H2S
  • Internal sample pump
    • Pull samples up to 125'
    • Maintain steady sample flow to sensors
  • Audible and visual alarms
    • 2 Ways to communicate with workers
  • Ideal for refinery applications

N/A

  • Provides ppm detection of combustible gas.
  • Barhole mode for tracking leak migration.
  • Leak check with changing blink / pulsing rate.
    • LED's and alarm tones increase in frequency as gas concentration increases.
  • Audible alarm silence.
    • Perform leak investigations without alarming residents.

Line Purge Testing

N/A
  • Thermal conductivity sensor.
    • 0 to 100% volume Methane / Hydrogen range.
  • Autoranging IR
    • Automatically changes from % LEL to % Vol.
    • Displays appropriate unit of measure.

N/A

  • Robust photo ionization detector (PID)
  • Two ranges available,
    • 0 to 50 ppm or 0 to 2000 ppm
  • Can be combined with other sensors to maximize capability
  • Method 21 compliant

N/A

  • Determine transformer health by sampling head space.
  • Measure Hydrogen (and other flammable gases) and Oxygen in nitrogen blanket.
  • Increasing flammable gas levels in head space indicates failing transformer.

Landfill Monitoring

N/A
  • LEL / PPM and 0 to 100% volume Methane.
  • 0 to 60% Carbon Dioxide range.
  • Can be combined with other sensors (O2/H2S/CO) to maximize capability.

User Selectable Options

N/A Alarm Latching Alarm Points Alarm Silence Auto Fresh Air Autocal Values Backlight Delay Bar Hole Measurement Time Battery Type Calibration Interval Calibration Past Due Action Calibration Reminder Catalytic Detection Units Combustible Gas Selection Configuring Channels Data Log Interval Data Log Memory Data Log Overwrite Date and Time Date Format Factory Default Language LCD Contrast Leak Check / Bar Hole Mode Lunch Break Operation Confirmation Alert Password Function On or Off Relative Response On or Off Span Factor User and Station ID

N/A Shoulder strap, alkaline batteries, hydrophobic probe, 5 foot hose, and internal hydrophobic filter.

N/A

  • Dilution fitting (50/50)
  • Ni-MH batteries
  • Battery charger, 115 VAC, 220 VAC, or 12 VDC (charge time 4 hours)/continuous operation adapter, 115 VAC or 12 VDC
  • Extension hoses

N/A

  • Monitor up to 6 different gases
  • PPM, % LEL, or % Vol. auto-ranging combustible detection
  • Specialty Sensors
    • PID (Photoionization Detector)
      • Low or high range for VOC detection
      • Fence Electrode Technology for humidity and contamination resistance
  • Infrared (IR) CO2, % LEL CH4, % Vol. CH4, % LEL HC, % Vol. HC
  • Thermal Conductivity (TC) % Vol. H2, % Vol. CH4
  • Smart toxic, plug and play sensors NH3, AsH3, Cl2, HCN, PH3, & SO2
  • Hydrogen specific LEL / ppm sensor
  • Powerful long-life pump up to 125’ range
  • Low flow pump shut off and alarm
  • Methane elimination for environmental use
  • Alkaline 18 hours or NiMH 20 hours capability
  • EPA Method 21 VOC Monitoring
  • Internal hydrophobic dust filter
  • External probe with hydrophobic filter
  • Multilingual (5 languages)
  • Ergonomic RFI / EMI / chemical / weather resistant enclosure
  • Intrinsically safe design, CSA approval
  • Datalogging standard
  • Low flow alarm shuts pump off to avoid damage to instrument.
  • Hydrophobic filter disc in probe.
  • Internal hydrophobic filter.
  • Single gas calibration capability.
  • Methane elimination feature for environmental applications.
  • Security Password protected.
  • Meets EPA Method 21 protocol for fugitive emissions testing (most applications).
  • Plug and play toxic sensors.
  • Datalogging available for all configurations.
  • Transformer gas testing version available.

Specialty Sensors

N/A The PID sensor is capable of detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases. Other smart sensors include % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; ppm or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges; Optional LEL / ppm H2 specific sensor, methane elimination feature for environmental applications; and a variety of super toxic gases. EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. Made In U.S.A

N/A The EAGLE 2 available features include a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases; % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges; methane elimination feature for environmental applications; and a variety of super toxic gases. The EAGLE 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 125 feet. This allows for quick response and recovery from distant sampling locations. The EAGLE 2 will continuously operate for over 18 hours on alkaline batteries or 20 hours on NiMH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, just to name a few. Data-logging is a standard feature for all sensors on all versions.

The Eagle 2 is ideal for performing EPA Method 21 fugitive emission monitoring of VOC leaks from process equipment.. EPA Method 21- Determination of Volatile Organic Compound Leaks, is a test method used for the determination of leaks of VOCs from process equipment. The Eagle 2 meets the requirements for portable instruments used for this purpose as outlined in Sections 6 and 8 of Method 21. For more info about Method 21, see the RKI FAQ; Do the RKI Eagle and Eagle 2 Portable Gas Monitors Conform to EPA Method 21 Performance Criteria?

N/A Specifications subject to change without notice.

Made in the USA.

  • 1 Standard 4 gas with batteries
  • 2 Non-condensing