- Specifications
- Packaging
- Display
- Relay Contact Rating
- Power Sources
- Dimensions
- Weight
- Features
- Applications
- Additional Information
Brands |
N/A RKI Instruments |
Detection Principle |
N/A Electrochemical |
Gas Detected |
N/A Carbon Monoxide (CO) |
Detection Range1 | N/A 0 to 150 ppm |
Display Resolution |
N/A 1 ppm |
Sampling Methods |
N/A Diffusion or Remote Sampling Method with Optional Sensor Extender Cable. |
Indication Accuracy (±)2 | N/A 5 %2 % of Full-Scale |
Response Time3 | N/A 90 % within 30 seconds (T90) % |
Alarm Levels4 | N/A Alarm 1 = 50 ppm Alarm 2 = 100 ppm Two Preset Alarms (L-H) |
Display of First Gas Alarm |
N/A Buzzer Flashing AL 1 Icon Gas Concentration Reading Blinks Orange Back Light |
Display of Second Gas Alarm |
N/A Buzzer Flashing AL 2 Icon Gas Concentration Reading Blinks Red Back Light |
Alarm Logic |
N/A Latching or Non-latching (Including Trouble Alarm) |
Alarm Contact |
N/A Dry Contact, Normally Open or Normally Closed (Default Setting is Normally Open) |
Trouble Alarm/Self-Diagnosis |
N/A System Trouble / Sensor Connection Trouble |
Display of Trouble Alarm |
N/A Buzzer / Flashing of Red Error Message |
Approvals |
N/A European Conformity (CE) Marking Standard. Canadian Standards Association (CSA) Approval Optional (No Power Cord Supplied with AC CSA Version) |
Output Signal |
N/A 4 to 20 mA (Non-Isolated, Resistive Load Under 300 ohms) or 0 to 1VDC (Non-Isolated) Only for 0 to 1VDC Alkaline Battery Specification. |
Extender Cable (Optional) |
N/A Extender Cable with Remote Box (3 m, 5 m, 10 m, and 20 m Lengths Available) |
Maximum Alternating Current (AC) Power Consumption |
N/A 3.5 V·A |
Maximum Direct Current (DC) Power Consumption |
N/A 2 W |
Continuous Operation5 | N/A 1 year |
Operating Temperature |
N/A -17 to 40 ºC0 to 104 ºF |
Operating Relative Humidity (RH) Range6 | N/A 0 to 90 % |
Mounting Equipment |
N/A Wall Mounting Type (By Using Accessory Mounting Plate or Mount at One Switch Box) Cable Inlet: Up, Down and Left/Right, or Rear Side. |
Material Warranty |
N/A 1 year |
Workmanship Warranty |
N/A 1 year |
Package Type |
N/A Each |
Units Per Package |
N/A 1 |
Display |
N/A Digital Liquid-Crystal Display (LCD) (3 Digits, 7 Segments / Green, Orange, Red) (For Alkaline Battery Version, The Back Light will be OFF During Normal Operation) |
Relay Contact Rating Alternating Current (AC) Voltage |
N/A 125 V |
Relay Contact Rating Current |
N/A 1 A |
Relay Contact Rating Direct Current (DC) Voltage |
N/A 30 V |
Note for Relay Contact Rating |
N/A Resistive Load |
Alternating Current (AC) Voltage |
N/A 120 V |
Alternating Current (AC) Voltage Tolerance (±) |
N/A 10 % |
Frequency |
N/A 50 Hz60 Hz |
Direct Current (DC) Voltage |
N/A 24 V |
Direct Current (DC) Voltage Tolerance (±) |
N/A 10 % |
Power Source |
N/A AA Alkaline Battery (2 Each) |
Body Width |
N/A 3.15 in80 mm |
Body Height |
N/A 4.72 in120 mm |
Body Depth |
N/A 1.2 in35.5 mm |
Alternating Current (AC) Specification Weight |
N/A 7.05 oz200 g |
Direct Current (DC) Specification Weight |
N/A 6.34 oz180 g |
Alkaline Battery Specification Weight |
N/A 8.11 oz230 g |
N/A
|
N/A
|
N/A
If Carbon Monoxide is present, the user is notified by an audible alarm tone and the multicolored LED digital display. |
- 1 1 ppm per Digit
- 2 Whichever is greater. Under normal conditions
- 3 Under normal conditions.
- 4 Other Settings Available
- 5 No Alarm, No Indication for Alkaline Battery Version
- 6 Non-condensing